-40%

VT DSO-2820R:200MHz 8~16Bit Multi-function PC USB Oscilloscope Spectrum Analyzer

$ 116.13

Availability: 16 in stock
  • Brand: VIRTINS TECHNOLOGY
  • Sample Rate: 200 MHz
  • Return shipping will be paid by: Buyer
  • Maximum Bandwidth: 80 MHz
  • Refund will be given as: Money Back
  • Channels: 2
  • All returns accepted: Returns Accepted
  • Digital Oscilloscope Resolution: 16-bit
  • Type: Digital
  • Condition: New
  • MPN: VT DSO-2820R
  • Number of Channels: 2
  • Item must be returned within: 30 Days
  • Model: VT DSO-2820R
  • Bandwidth: 80 MHz
  • Oscilloscope Type: Digital Storage Oscilloscope (DSO)

    Description

    VT DSO-2820R
    Second-Generation 200MSPS 80MHz 8~16Bit Precision PC USB Oscilloscope, Spectrum Analyzer, Multimeter
    with a hardware activated Multi-Instrument (Standard) software license
    Turn a PC into multiple virtual instruments!
    1. Introduction
    This is one of the second-generation USB DSOs designed and developed by Virtins Technology. This generation of USB DSOs features Virtins Technology’s unique hardware-based DSP algorithm which enhances the performance and functionality dramatically. When used in conjunction with Multi-Instrument® software, the USB DSO converts any desktop, laptop, or tablet PC into a powerful oscilloscope, spectrum analyzer, multimeter, data logger, signal generator and so forth, all of which work simultaneously.
    Feature Highlights
    8~16 Bit 200MSPS 80MHz Oscilloscope and Spectrum Analyzer
    2 analog input, 1 digital output
    Unique hardware based DSP algorithm
    Sophisticated trigger function
    10 voltage ranges, 1% DC accuracy
    Adaptive anti-aliasing filter
    Streaming Mode supported
    Very small footprint (70 x 24 x111 mm)
    A comprehensive suite of time-domain, frequency-domain and time-frequency domain processing and analyses.
    Multi-Instrument software can be downloaded from virtins.com for a 21-day fully functional FREE trial using your sound card as the ADC and DAC device
    2. Package Contents
    1)
    VT DSO-2820R unit with a hardware activated Multi-Instrument Standard software license
    2)  2
    ´
    100MHz Oscilloscope Probe P2100 with two switchable positions:
    ´
    1,
    ´
    10
    3)  USB cable (1.5 m)
    4)  CD (contains the copy-protected Multi-Instrument software and VT DSO-2820R driver)
    3. VT DSO-2820R Hardware Specifications
    Oscilloscope Horizontal (Time) Axis
    Real Time Sampling Frequency (f
    s
    )
    Single Analog Channel
    200 MHz
    Single or Dual Analog Channels
    100 MHz, 50 MHz, 25 MHz, 20 MHz, 10 MHz, 5 MHz, 4 MHz,
    2 MHz, 1 MHz, 500 kHz, 400 kHz, 200 kHz, 100 kHz,
    50 kHz, 40 kHz, 20 kHz, 10 kHz, 5 kHz, 4 kHz, 2 kHz,
    1 kHz, 500 Hz, 400 Hz, 200 Hz, 100 Hz, 50 Hz, 40 Hz,
    20 Hz, 10 Hz, 5 Hz, 4 Hz, 2 Hz, 1 Hz
    Equivalent Sampling Frequency
    = [Real Time Sampling Frequency]
    ´
    [Number of Frames Persisted]. Maximum 40 GHz, for repetitive signals whose maximum frequency is less than ¼ of the real time sampling frequency. Not valid for the case of post-trigger.
    Buffer Size
    Normal Frame Mode
    Analog
    Single Channel
    40000 samples (8 bits)
    20000 samples (16 bits)
    Dual Channels
    20000 samples / channel (8 bits, Non-ALT mode) 10000 samples / channel (16 bits, Non-ALT mode)
    40000 samples / channel (8 bits, ALT mode)
    20000 samples / channel (16 bits, ALT mode)
    Record Mode
    (Streaming Mode)
    Limited only by hard disk space available.
    Maximum sampling frequency for continuous streaming is computer
    speed
    and software setting dependent and typically 10 MHz
    (single channel, 8 bit) in Multi-Instrument.
    Roll Mode
    (Streaming Mode for Low Frequency Signals)
    Limited only by the computer memory available.
    Roll Mode is allowed when f
    s
    £
    1MHz and [Record Length]
    ³
    4
    ´
    [Roll Width]. Maximum sampling frequency for continuous streaming is computer
    speed
    and software setting dependent.
    Sweep Time
    5 ns ~ 500 s (Non-Streaming Mode)
    Sampling Frequency Accuracy
    ±
    50 ppm
    Oscilloscope Vertical (Analog) Axes
    Number of Channels
    2
    (i.e. Ch. A and Ch. B)
    ADC Bit Resolution
    8 Bits
    Enhanced ADC Bit Resolution
    (available only when Sampling Frequency is less than 100 MHz)
    16 Bits
    If this option is selected, the effective bit resolution increases from 8 bits to up to 16 bits as the sampling frequency goes down.
    (Assuming white noise in the signal)
    Sampling Frequency
    Effective Bit Resolution
    Sampling Frequency
    Effective Bit Resolution
    ³
    100 MHz
    8 Bits
    £
    25 MHz
    9 Bits
    £
    6.25 MHz
    10 Bits
    £
    1.563 kHz
    11 Bits
    £
    391 kHz
    12 Bits
    £
    97.7 kHz
    13 Bits
    £
    24.4 kHz
    14 Bits
    £
    6.10 kHz
    15 Bits
    £
    1.526 Hz
    16 bits
    Bandwidth
    f
    s
    >
    50 MHz
    80 MHz
    f
    s
    £
    50 MHz
    8 Bits
    No Effective Bit Resolution Enhancement
    80 MHz
    Effective Bit Resolution Enhancement
    15 ~ 25 MHz
    16 Bits
    Effective Bit Resolution Enhancement
    about 0.443 f
    s
    Voltage Measuring Range
    (Full Scale)
    ±
    50 mV,
    ±
    100 mV,
    ±
    200 mV,
    ±
    500 mV,
    ±
    1 V,
    ±
    2 V,
    ±
    5 V,
    ±
    10 V,
    ±
    20 V,
    ±
    50 V
    Max. Allowed Voltage
    ±
    100 V
    (DC + AC peak), derated above 100kHz
    DC Accuracy
    ±
    1%
    Coupling Type
    AC / DC
    Input Isolation
    No (Isolation can be achieved through a USB isolator)
    Terminal Type
    Referenced Single-Ended, BNC
    Input Impedance
    1 M
    W
    , 15 pF
    Zero Calibration
    Through software. Individually done at factory
    Gain Calibration
    Through software. Individually done at factory
    Oscilloscope Trigger
    Trigger Detection Method
    Digital
    Trigger Source
    Ch. A, Ch. B, ALT
    Trigger Mode
    Auto, Normal
    , Single, Slow
    Trigger Edge
    Rising, Falling
    Trigger Level
    Adjustable within full scale
    Pre-Trigger
    -100% ~ 0% of
    Record Length
    Post-Trigger
    0 ~ 100% of Record Length
    Trigger Frequency Rejection
    Nil: No Rejection
    HFR: High Frequency Rejection, cut off at 0.11
    f
    s
    NR0: Noise Rejection, hysteresis = 1% of half of full scale
    NR1: Noise Rejection, hysteresis = 2% of half of full scale
    NR2: Noise Rejection, hysteresis = 4% of half of full scale
    NR3: Noise Rejection, hysteresis = 8% of half of full scale
    NR4: Noise Rejection, hysteresis = 16% of half of full scale
    HN0: HFR + NR0
    HN1: HFR + NR1
    HN2: HFR + NR2
    HN3: HFR + NR3
    HN4: HFR + NR4
    HNX: selectable HFR + adjustable hysteresis = 0% ~ 25% of half of full scale
    Note: The specified hysteresis may be modified internally to ensure [Trigger Level (%)] – [Hysteresis (%)]
    ³
    -100% at rising edge, or [Trigger Level (%)] + [Hysteresis (%)]
    £
    100%] at falling edge.
    Oscilloscope Dynamic Performance (Typical)
    THD
    f
    s
    =100 kHz, f=1 kHz, from 2
    nd
    to 20
    th
    order, full-scale input:
    8 bits (without bit resolution enhancement):
    £
    -55 dB
    8 bits (with bit resolution enhancement):
    £
    -56 dB
    16 bits:
    £
    -59 dB
    IMD (250 Hz + 8 kHz, 4:1)
    f
    s
    =100 kHz, from 2
    nd
    to 3
    rd
    order, full-scale input:
    8 bits (without bit resolution enhancement):
    £
    -51 dB
    8 bits (with bit resolution enhancement):
    £
    -52 dB
    16 bits:
    £
    -57 dB
    IMD (19 kHz +20 kHz, 1:1)
    f
    s
    =100 kHz, 2
    nd
    order only, full-scale input:
    8 bits (without bit resolution enhancement):
    £
    -65 dB
    8 bits (with bit resolution enhancement):
    £
    -65 dB
    16 bits:
    £
    -78 dB
    SFDR
    f
    s
    =100 kHz, f=1 kHz, full-scale input:
    8 bits (without bit resolution enhancement):
    ³
    61 dB
    8 bits (with bit resolution enhancement):
    ³
    61 dB
    16 bits:
    ³
    62 dB
    Crosstalk
    £
    -45 dB (at the same voltage measuring range for full bandwidth)
    Noise
    For voltage measuring ranges
    ±
    50 mV and above:
    8 bits (without bit resolution enhancement):
    £
    ±
    3 counts (
    ±
    1%)
    8 bits (with bit resolution enhancement, f
    s
    =100 kHz):
    £
    ±
    2 counts (
    ±
    0.8%)
    16 bits (f
    s
    =100 kHz):
    £
    ±
    0.3 8-bit count (
    ±
    0.1%)
    Signal Generator General
    Number of Channels
    1 (digital signal only)
    Coupling Type
    DC
    Output Isolation
    No
    Terminal Type
    Referenced Single-Ended, Probe Calibration Connector
    Output Impedance
    About 600
    W
    Overvoltage Protection
    ±
    35 V
    Signal Generator
    -
    Digital (when Signal Generator is not running)
    Voltage Range
    0 ~ 3.3 V, not adjustable
    Output Signal Frequency Accuracy
    ±
    50 ppm
    Bandwidth
    13 MHz
    Rise Time (10% ~ 90%)
    < 50 ns
    Waveform
    Square
    Signal Frequency
    25 MHz / N, (N=1, 2, 3, ….25000)
    MLS
    Sampling Frequency
    25 MHz / N, (N=1, 2, 3, ….25000)
    General
    Interface
    USB 2.0 High Speed / USB 1.1 Full Speed / USB Isolator
    Device Category in Multi-Instrument
    ADC Device
    VT DAQ 1
    DAC Device
    Not Applicable
    Firmware Upgradable
    Yes
    Power
    Bus powered by USB port, no external power source required.
    Power Consumption
    Max. 1.5W
    Dimensions
    111 mm (L)
    ´
    70 mm (W)
    ´
    24 mm (H),  Metal Casing
    System Requirement
    Windows XP, Vista, 7, 8, 10 or above, 32 bit or 64 bit
    Operating Temperature
    0
    °
    C ~50
    °
    C
    4. Introduction of Multi-Instrument (Standard)
    Multi-Instrument (Standard) is a powerful PC based multi-function virtual instrument software. It supports a variety of hardware ranging from sound cards which are available in almost all computers to proprietary ADC and DAC hardware such as VT DSO, VT IEPE, VT CAMP, VT RTA, NI DAQmx cards and so on. It consists of a dual trace oscilloscope, a real time spectrum analyzer, a signal generator and a multimeter, and can run them simultaneously.
    For a sound card based system, software triggering is supported.  It features a specially designed data acquisition approach, which is able to monitor the input signal continuously without missing any trigger event before a frame of data is collected. It has a very fast screen refresh rate (typically greater than 50 frames per second). It supports sophisticated triggering method including pre-trigger and post-trigger. Both level trigger and differential trigger are supported.
    For a non sound card based system, the triggering capability depends on the hardware used. Hardware triggering is supported if the hardware used supports it.  Software triggering is supported if the hardware used supports data streaming.
    The software has a multilingual user interface, including English, French, German, Italian, Spanish, Portuguese, Russian, Simplified Chinese, Traditional Chinese, Japanese, and Korean.
    It has been widely used in education, scientific research, audio engineering, electronic engineering, medical diagnosis, vibration analysis, etc.
    The software can be downloaded from virtins.com for a 21-day fully functional FREE trial using your sound card as the ADC and DAC device.
    5. Functions of Multi-Instrument (Standard Version)
    A comprehensive range of functions are provided in Multi-Instrument (Standard), including:
    (1) Oscilloscope
    Oscilloscope Mode: dual-trace waveform, waveform addition, subtraction and multiplication, Lissajous Pattern, transient signal recording, voltmeter. AM, FM, PM Demodulation. Linear and exponential average...
    Record Mode: Record data to the hard disk continuously until the recording process is stopped manually or 2 gigabytes of data has been recorded, whichever  is earlier. During the recording process, acquired data will still be analyzed and displayed to keep the screen updated in real time.
    Roll Mode: Data displayed in the Oscilloscope will shift left gradually while the newly acquired data are added from the right.
    (2) Spectrum Analyzer
    RMS amplitude spectrum, relative amplitude spectrum, octave analysis (1/1,1/3,1/6,1/12,1/24, 1/48, 1/96), frequency compensation, frequency weighting (A,B,C,ITU-R 468), moving average smoothing, peak hold, linear average, exponential average, measurement of THD, THD+N, SNR, SINAD, Noise Level, IMD, Bandwidth, Crosstalk, Harmonics, Peaks, and Energy in user defined frequency bands, phase spectrum, auto correlation function, cross correlation function...
    (3) Signal Generator
    Function generation, multitone generation, arbitrary waveform generation, burst tone generation, MLS generation, DTMF generation, musical scale generation, white noise and pink noise generation, and frequency/amplitude sweep signal generation. Fade In / Fade Out of the output signal, AM, FM, PM modulation...
    (4) Multimeter
    RMS, dBV, dBu, dBSPL, dB(A), dB(B), dB(C), Frequency Counter, RPM, Counter, Duty Cycle, Frequency/Voltage Conversion, Cycle RMS, Cycle Mean.  The latter seven modes involves a pulse counting process, with the counter trigger level, hysteresis, frequency dividing ratio adjustable.
    6. License information and Function Allocation in Multi-Instrument Series
    The full package of Multi-Instrument has six levels and five add-on modules/functions.
    The six levels are: Sound Card Oscilloscope (listed price US.95), Sound Card Spectrum Analyzer (listed price US.95), Sound Card Signal Generator (listed price US.95), Multi-Instrument Lite (listed price US.95), Multi-Instrument Standard (listed price US.95), Multi-Instrument Pro (listed price US9.95).
    The five add-on modules/functions are: Spectrum 3D Plot (listed price US.95), Data Logger (listed price US.95), LCR Meter (listed price US.95), Device Test Plan (listed price US.95), Vibrometer (listed price US.95).
    Note: The item here contains one hardware activated license of Multi-Instrument (Standard) without any add-on modules/functions. "Hardware activated" means that the VT DSO-2820R hardware unit must be connected to the computer in order for the software to work under the licensed mode.  Otherwise the software will work in 21-day fully functional trial mode. No softkey (activation code) will be given under the hardware activated license.
    Please refer to virtins.com/multi-instrument.shtml for the function allocation matrix for the six levels of Multi-Instrument.
    7. Extended use of the Multi-Instrument Software
    With the VT DSO-2820R unit connected to the computer, the Multi-Instrument software will run under the licensed mode. In Multi-Instrument, the ADC device and DAC device can be independently selected. For example, you can use the VT DSO-2820R as the ADC device and your computer's sound card as the DAC device, and they can work simultaneously. Or, you can use the sound card for both ADC and DAC.
    Note: the test lead (or probe) for sound cards is not included in this package, but you can make the connection by yourself or purchase it from us separately.
    Specification for a sound card based system:
    Scan Time:                    100µs~500s*
    Sampling Rate
    *
    :             Max. 768 kHz
    Bandwidth
    *
    :                  10Hz~200kHz
    Bit Depth
    *
    :                    8, 16,24
    Voltage Range
    *
    :            Max -1V~1V
    Input Channel:               Ch.A, Ch. B
    Output Channel:            Ch.A, Ch. B
    Trigger Mode:               Auto, Normal, Single, Slow
    Trigger Edge:                 Rising, Failing, Differential
    Trigger Delay:                Pre-Trigger, Post-Trigger
    Trigger Source:              Ch. A, Ch. B
    FFT Size:                      128~4194304
    Window Functions:        55 types
    Window Overlap:          0%~99%
    Octave Analysis:            1/1, 1/3, 1/6, 1/12, 1/24, 1/48, 1/96
    Frequency Weighting:    A, B, C, ITU-R 468
    *
    Sound Card dependent
    * Computer Memory dependent
    For a non sound card based system:
    Please refer to the respective hardware manual.
    8. System Requirement
    PCs, laptops or tablets with
    Microsoft Windows XP or later, with a USB port.  Both 32 bit and 64 bit Windows are supported. Screen horizontal resolution is recommended to be equal to or greater than 1024 pixels.
    For a sound card based system, 8, 16 or 24 bit Windows compatible sound card is required.
    The software also supports NI DAQmx cards such as NI USB 6009.
    9. Software Upgrade policy
    Software upgrade for the same license level is always FREE. When a new version is available, you can just uninstall your current version, download and re-install the new version, as long as the VT DSO-2820R unit is still supported by the new version.
    Software upgrade to a higher level can be purchased from virtins.com. The software license activated by VT DSO-2820R is remotely upgradable.
    10. Shipping
    We ship worldwide.
    The item will be shipped via express mail service within 24 hours after the payment is received. It will take normally about 5~8 days to deliver to you (e.g. USA, UK, Australia, Canada, Hong Kong, Taiwan, Japan, Korea...).  In some specially cases, or special places (e.g. Italy), it may take a little longer time. The shipping and handling charge is fixed at US for all places. Tracking information online will be provided 2 days after shipping.
    You MUST provide us your telephone number as required by the courier company to facilitate the delivery!
    11. Refund Policy
    One year warranty against defective materials and manufacturing defects for all hardware parts inside the package.
    Return for malfunctional item is accepted for refund within 7 days after you receive the item.  For full refund, the package must be in the same condition as received with all accessories.  The returned item must be delivered with postage prepaid by the customer.  You must contact us first before you return it. We strongly recommend that you try out the Multi-Instrument software from virtins.com first before you buy it. Please contact us if you are in doubt before you place the order.