-40%

TEST PRODUCTS INTERNATIONAL(TPI 460) 20Mhz Handheld Oscilloscope, FREE SHIP NEW!

$ 438.02

Availability: 100 in stock
  • Brand: TEST PRODUCTS INTERNATIONAL (TPI)
  • MPN: 460
  • Bandwidth: 20MHz
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Refund will be given as: Money Back
  • Restocking Fee: No
  • Country/Region of Manufacture: Korea, Republic of
  • Type: OSCILLOSCOPE
  • Model: 20MHz HANDHELS DIGITAL O-SCOPE
  • Return shipping will be paid by: Seller
  • Condition: New

    Description

    THIS SALE IS FOR A NEW TPI 460 20MHz DIGITAL O-SCOPE, IN ORIGINAL CASE, WITH ALL DOCUMENTS, AND ALL ACCESSORIES INCLUDED FROM THE FACTORY. THE ORIGINAL CARDBOARD BOX IS NOT INCLUDED. THIS UNIT IS BRAND NEW NEVER USED AND HAS NEVER BEEN REGISTERED WITH THE FACTORY FOR THE FACTORY WARRANTY. IT WAS PURCHASED FOR A DEFENSE CONTRACT THAT NEVER RECEIVED FULL FUNDING. THE COMPANY HAD WRITTEN THEIR NAME ON THE BACK OF THE SCOPE. I  CAN REMOVE IT AS THE GHOSTING OF THAT WRITING  CAN STILL BE SEEN, AND  I WANT TO BE PERFECTLY HONEST AS ALWAYS. THE UNIT STILL HAS THE REMOVABLE SCREEN PROTECTOR ON IT, IT WAS NEVER TAKEN OFF. UNIT HAS BEEN FULLY TESTED AND IS PERFECT!! UNIT PART NUMBER= TPI 460. THIS UNIT HAS A RETAIL OF 0.58 AND WORTH EVERY PENNY OF THAT!!!
    WHY NOT SAVE A BOATLOAD OF CASH, YOU ARE GOING TO TOSS THE CARDBOARD EXTERIOR BOX ANYWAY AND THE GHOSTED IMAGE ON THE REAR HAS ZERO EFFECT ON FORM/FIT/FUNCTION.
    This item qualifies for eBay Fast N Free - 1 day handling and free domestic shipping with Fedex
    Ground/Home OR USPS GROUND, UPS GROUND OR OTHER TRACKABLE CARRIER to the lower 48 USA.
    AK, HI, PR to pay actual shipping.
    TPI 460 20Mhz Handheld Oscilloscope
    Item specifics
    Condition:
    New:
    A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is
    ...
    Read more
    about the condition
    Brand:
    TEST PRODUCTS INTL.
    Sampling Rate:
    25MSa/s Single Channel, 500MSa/s Second Channel
    ManufacturerPartNumber:
    460
    Manufacturers Warranty Length:
    3 Years
    SKU:
    G4676296
    Battery Life:
    2.5 Hours With Backlight On
    Item:
    Handheld Oscilloscope
    Bandwidth (MHz):
    20
    Display:
    3"x3" Cold Cathode Florescent
    Input Sensitivity:
    50mV/div to 200V/div
    Safety Rating:
    CAT II 1000V, CAT III 600V
    Product Features
    20 MHz Bandwidth
    Enough bandwidth to capture signals from AC/DC drive motors, sensors, actuators, line and control voltages, UPS and industrial machines.
    Sample Rate
    A real time sampling of 25 megasamples/sec to capture spikes and dropouts of industrial signals.
    Dual Input
    View two waveforms on the display for comparison and troubleshooting.
    True RMS DMM
    Includes a 4000 count True RMS DMM that measures AC/DC volts to 600, frequency to 20MHz, resistance to 20MegOhm, diode test and continuity buzzer.
    Bright LCD Backlight
    Easy-to-see in any light conditions with user-adjustable brightness levels.
    Optically Isolated RS232 Output
    Transfer data safely without any direct connections to your computer’s systems circuitry.
    What's in the Box?
    TPI 460 digital oscilloscope and multimeter
    Set of insulated test leads with alligator clips
    7.2V rechargeable NiCad battery pack
    Charger/adapter
    User manual
    Optional Accessories:
    Temperature Adapter to measure temperature from -40 to 500°F (A301)
    Pressure Adapter to measure pressure from -30 to 500psi (A620)
    Current Adapters • For measuring low current in milliamps (A254) • Up to 400AC/DC amps (A256) • And up to 1000 AC/DC amps (A296)
    Protective Boot (A405)
    Soft Carrying Case with shoulder strap (A905)
    Software and RS232 cable (A404)
    Applications
    Industrial motor control View start-up in rush currents, waveform symmetry, SCR trigger pulses, variable frequency drive signals, pulse width modulation, noise, misc. AC and DC speed control signals.
    Power quality Noise on industrial feeds, AC voltage waveshape, current waveforms, machine start-up/power quality interference and noise.
    Programmable logic controls PLC input and output signals, control signals, signal conditioning circuits, communications lines and power supplies.
    NC machines Power quality, sensor outputs, control circuits, safety circuits, calibration and adjustments.
    Uninterruptable power supplies Sensing and monitoring circuits, switching circuits, output waveforms and current waveforms.
    Audio Public address feeds, amplifiers, mixers and preamps.
    Video Horizontal and vertical scan rates, z-axis blanking, sync pulses and luminance.
    Industrial lighting controls SCR’s and other solid state designs.
    Factory automation Robot control signals, machine vision, machine control and sensing circuits, calibration of positioning systems, analog controllers and servo controls.
    Line conditioners Noise and quality.
    Voltage regulators Noise and stability.
    Inverters Waveform quality.
    The 460 hand held oscilloscope features a 3” x 3” cold cathode fluorescent display providing test data in a clear easy to see format. The cursor readout function allows the width and amplitude of a signal to be measured precisely instead of trying to figure it out manually.
    20 MHz Bandwidth
    Cursor Readout
    Decibels
    Pre and Post Triggering
    Trend Mode
    Dual Input
    True RMS DMM
    Real Time Sample Rate
    Bright LCD Backlight
    Optically Isolated RS232 Output
    Continuous Autoset
    460 Specifications
    DISPLAY
    Size
    3” x 3” (76mm x 76mm)
    Pixels
    240 x 240
    Backlight
    Yes
    POWER
    External
    5V DC power supply (Included)
    Internal
    4.8V DC rechargeable battery
    Operating Time
    2.5 Hours with backlight on
    Charging Time
    10 Hours
    MEMORY
    Waveform
    Save 2 full screens
    Setup
    Saves user settings
    VERTICAL
    Sample Rate (-3dB)
    Real Time: 25 Megasamples per Second up to 2 MHz
    Equivalent Time: 500 Megasamples per Second > 2 MHz
    Bandwidth
    20 MHz w/SP60B 10:1 Probe
    10 MHz w/Shielded Test Leads
    Resolution
    8 bits
    Channels
    2
    Coupling
    AC, DC AC, DC, GND (max: 750V)
    Input Impedance
    Approximately 1M Ohm
    Sensitivity
    50mV TO 200V/div 1,2,5 Sequence
    Accuracy
    ± 3% ± (3% + 0.05 range/div)
    Trigger Position
    Ver1;Fixed Position / Ver3; Adjustable Position
    Trigger Mode
    Free Run, Normal
    Trigger Source
    Internal
    Trigger Slope
    Positive / Negative
    Trigger Sensitivity
    Equivalent Time: 3 divisions or more
    Real Time: 2 divisions or more
    HORIZONTAL
    Samples per Division
    25
    Time / Division
    50nS to 500nS / DIV (equivalent times)
    1uS to 2S / DIV (real time)
    Modes
    Single, Normal, Auto
    Accuracy
    Equivalent Time : ± (0.5% + 0.08 time/div)
    Real Time: ± (0.1% + 0.04 time/div)
    TREND MODE
    Plot Time
    30 sec/div to 1 hour/div
    Plot Data Type
    Max/Min Selectable
    Memory
    2 Screens
    TRUE RMS DMM
    DCV (CH1, CH2)
    400mV, 4, 40, 400, 600V
    Basic DC Accuracy
    ± (0.5% + 5 digits)
    ACV (CH1, CH2)
    400mV, 4, 40, 400, 600V
    Basic ACV Accuracy
    ± 0.75% ± (1% + 10 digits)
    Frequency (CH1, CH2)
    1 Hz to 20 MHz
    Basic Frequency Accuracy
    ± (0.5% + 5 digits)
    Ohm (CH1 only)
    400, 4k, 40k, 400k, 4M, 20M
    Basic Ohm Accuracy
    ± (0.5% + 5 digits)
    Continuity (CH1 only)
    < 0.1k ohm, ± (2% + 5 digits)
    Diode Test
    5mA maximum output
    460 Applications
    Power Quality
    Variable Speed Drives
    Industrial Motor Controls
    Battery Testing
    Programmable Logic Controls
    NC/CNC Machines
    Uninterruptable Power Supplies
    Audio
    Video
    Industrial Lighting Controls
    Factory Automation
    Line Conditioners
    Voltage Regulators
    Inverters
    Gaming Industry
    Oscilloscopes FAQs
    Where do I use your oscilloscopes?
    They are ideal for viewing industrial power signals, UPS systems, power supplies and PLC controls. Use anywhere a DMM is used.
    Does the oscilloscopes measure capacitance?
    Yes, the 440 can measure up to 400uF (microfarads).
    What is the highest voltage the oscilloscopes can measure?
    They can measure up to 1,000 DCV and 1,000 ACV.
    What is the lowest voltage the 440 can measure?
    The 440 can measure down to 0.1 millivolts on both DCV and ACV. The scope also has a volts/division setting of 0.1 volts.
    How is the RS232 port used?
    With the optional A402 cable and software you can acquire data and download it to a spreadsheet.
    Can your oscilloscopes measure more than 10 DCA or ACA?
    Yes, TPI offers a number of amp adapters to extend the range up to 1,000 amps. TPI has a wide range of optional accessories that enables the user to measure amps, temperature, pressure, or CO.
    Why do you need a 20 MHz oscilloscope (460)?
    To measure signals and voltage anomalies, and to look for glitches that may damage or even shutdown electronic machinery. View sine waves on power supplies, motors, and bead board circuitry. Pinpoint certain glitches on the sine wave to zero inon the problem and monitor changing patterns or distortion in electrical currents.
    What are the different waveform patterns displayed on your handheld oscilloscopes?
    An AC waveform known as sine wave displays voltage against time in the shape of a sine curve. The saw toothwave form displays a ramped angleand a sharp downward return to its earlier value. (Its display pattern resembles the cutting edge ofa saw.) A square waveform graphically plots a series of vertical square shapes repeated with spacing between peaks.
    Why is it important to have Trend Mode?
    Trend Mode is great for monitoring sudden intermittents caused by loose connections, dirt, or damaged wires. By setting the minimum and maximum parameters, you can monitor, even record the changes.
    What is the purpose of triggering?
    Simply zoom in on certain parts of the sine wave and “hold” to measure and monitor that particular part you are reading. A must have when searching for glitches and distortion on all measurements.