Selling Lecroy SDA 11000 11 GHz, 40 GS/s Serial Data Analyzer Oscilloscope, CALIBRATEDUnit has been calibrated 12.7.2021 and is in excellent working condition. Please see pictures!
Includes the following accessories:
Fresh Calibration Certificate
4 x LeCroy HFP2500 Actice Probe, 2.5GHz
LeCroy ZS1000, 1GHz Active Probe
LeCroy OE525, DC-4.5GHz O/E Converter
LeCroy AP-1M, Hi-Z Buffer
LeCroy LPA-BNC Oscilloscope Adapter
LeCroy OE555, DC-3.5GHz O/E Converter
LeCroy manuals for SDA 11000 & Probes
LeCroy trolly (Please note that the shipping price will increase if you wish to have the trolly as well)
Description
(took from manufacturers webpage)
Total Solution for Next Generation Serial Data Analysis
With serial data quickly becoming a dominant form of data transmission, fast and accurate analysis becomes a priority.
The LeCroy SDA integrates all the key measurement and analysis tools into one device.
Here are a few of the measurements that are part of this powerful analyzer’s capabilities:
•
Serial data measurements up to 6.25 Gb/s
•
Supports testing of next generation serial data standards:
– 5 Gb/s PCI Express™ Gen2
– 4.25 Gb/s Fiber Channel
– 6 Gb/s SATA III / SATA II
– 4.8 Gb/s FB-DIMM
– 6.25 Gb/s double XAUI
•
Capturing up to 12 million UI in a single acquisition allows measurements on important low frequency effects, such as spread spectrum clocking, and switching converter noise
•
The latest LeCroy DSP technology brings you uncompromised uniformity in frequency and phase response resulting in dependable eye pattern representation
•
Configure PLL response in software clock recovery for any standard or custom requirement
Powerful Scope Performance Supports Serial Data Analysis
X-Stream Technology— Proprietary technology that enables data processing that is 10–100 times faster.
The SDA 11000 features:
11 GHz bandwidth with tightly controlled frequency response
28 ps rise time (20 to 80%, typical)
11 GHz on 2 channels 6 GHz on 4 channels
One touch to Serial Data Analysis
Sampling rates to up 40 GS/s with deepest memory 16M@2 Ch/8M@ 4 Ch Standard 32M@2 Ch/16M@ 4 Ch Option L 100M@2 Ch/50M @4 Ch Option XL
Wavepilot – provides easy access to powerful signal analysis capabilities.
Front panel USB
Advanced Analysis Tools
Turbocharge Your Jitter Measurements
Many different instruments such as sampling oscilloscopes, time interval analyzers (TIA’s) and bit error rate test sets are used to evaluate the jitter in serial data streams.
The SDA 11000 is the first DSO to implement all of these methods.
With a single instrument, the slight differences among methods can be viewed and understood.
The SDA 11000 provides specific jitter measurements to meet all serial data standards
Jitter Wizard
This feature automatically selects all of the critical instrument settings, ensuring the highest accuracy and repeatability.
• Sampling rate, level, bit rate and pattern length are automatically detected.
ISI Plot
The ISI plot displays data dependent jitter contributions to the eye pattern for the second-to-last bit of a bit length, set from 3 to 10.
This plot measures data dependent jitter without the need for a repeating bit pattern.
Edge-to-Edge Jitter
In this mode, timing is measured on data transitions relative to one another in the same way as a timing interval analyzer (TIA).
• Measurements can be displayed directly or compensated to correlate with phase jitter measurements.
• Tj, Rj, and Dj measurements can be made at specific UI spacings or for all spacings in the data stream.
Filtered Jitter
The SDA 11000 offers a filtered jitter mode to support ITU-T and SONET measurements.
• Band-pass filter with selectable upper and lower cutoff frequencies supplied.
N-cycle vs. N Jitter Plot
This display shows the rms jitter as a function of the UI spacing.
This display provides a very sensitive way of viewing periodic jitter effects.
The minimum value of this plot gives the rms value of the random jitter
Jitter Analysis: Rj, Dj, Tj
The SDA measures total jitter by extrapolating the histogram of jitter measurements.
It includes the following three methods for determining the random and deterministic components to support all existing standards:
Conventional. Deterministic jitter is measured directly and Rj is the difference between the total and deterministic parts.
Effective. BERT-scan method using the bathtub curve to fit a “dual dirac” jitter model.
MJSQ. Fibre Channel method using two Gaussian curves to fit the extremes of the measured distribution.
A Sharp Focus for Eye Patterns
Eye pattern analysis is a widely used tool for assessing the signal integrity of serial data streams.
The SDA measures eye patterns on a continuous record of up to 12M consecutive unit intervals (UI).
A software-defined clock recovery algorithm is used to separate the record into segments that are one UI in length and the segments are then overlaid to form the eye pattern.
Subsequent acquisitions are accumulated with the previous ones.
Consecutive UI ensures the capture of transient events on any single bit.
Eye pattern measurement compliant for PCI Express, Serial ATA, USB 2.0 and Serial Attached SCSI
Trigger jitter is eliminated, giving a measurement jitter that is 7x lower than traditional methods of measuring eye patterns.
Fully programmable clock recovery algorithm, including first- and second-order PLL models, provides compliance to all existing standards and allows the modeling of specific receiver types.
Clock recovery modes for PCI Express, DVI/HDMI and “GOLDEN” PLL.
Fast update rate for both electrical and optical signals with reference receiver
The Cleanest Eye Patterns Possible
Eye violation location displays individual bits that violate the eye mask boundaries.
The SDA measures eye patterns on consecutive unit intervals of the data stream under test.
The original waveform is indexed by the software so that the parts of the overall waveform that violate the mask boundaries, when formed into an eye pattern, can be identified by the particular bit that caused them.
The signal waveform around the failed bit is displayed, and relationships between the failure and adjacent bits can be easily seen.
A second channel from the instrument can also be displayed and time-aligned with the signal under test, to locate relationships between failures and other signals in the system under test.
Standards Compliance
The SDA 11000 offers a growing list of compliance packages to support everything from USB 2.0 to PCI Express.
These optional packages enhance the basic analysis and debug capabilities of the SDA by adding specific compliance measurements and displays.
Simple single-button operation can be invoked to perform an entire set of measurements and to display all results, including a pass/fail indicator.
LeCroy continues to add new measurements to the SDA to support current and emerging serial data standards.
Serial Number:
LCRY0408N11901
Terms & Conditions
_____________________________________________________
This sale includes the equipment ONLY.
No other parts or accessories will be included unless otherwise mentioned in the sales notification.
Payment
Full payment is due within 3 business days from sale unless separately agreed otherwise in advance.
Please note that all prices are VAT (tax) excluded and EXW Finland office (EXW = Ex Works).
In case you are:-
A private purchaser inside EU
, please note that
tax (VAT 24%) will be added
to the price
-
A business buyer inside EU
(except from Finland), please provide us your valid VAT number and the
price stays the same
(no VAT 24% will be added)
-
Outside European Community VAT
is
not applied
-
Finnish business buyer / private persons
,
tax
(VAT 24%)
will be added
to the price
Shipping and Handling
International shipping is available!
All items are packaged with care to ensure full protection during transit.
We ship packages with Fedex and freight with TNT unless requested otherwise.
*All courier shipments are insured based on the unit’s value and not weight*
Letters can be selected to shipped with either standard postal services (no insurance nor tracking code) or with courier services (includes the insurance and tracking code).
Most items are Shipped within 2 business days of cleared payment.
Orders placed after 10 a.m. GMT+2 Friday will ship the following Monday
Please note that the goods are sold “as is, where is” basis, EXW Raisio, Finland (Incoterms 2010), if not mentioned otherwise.
Buyer is responsible for taxes, duties and other possible import charges.
Warranty and Returns
A 5 Star Positive Rating is important to us!
Contact us within 14 days after receiving the purchased unit to request a refund if you notice any failure (If the item includes warranty). Please explain the failure in details with pictures included and pack the unit to the same box it was delivered to you. We will order a return ticket for the failing unit. We will issue the full refund of the unit price after receiving the unit back to us. Please note that as a buyer you are responsible for the return shipping & handling charges.
If the product is damaged due to the Buyer's mis-handling or return shipping process, we will not refund, and we will notify eBay for return policy abuse.
AS-IS items are sold without warranty
Buyer pays shipping charges for returned items
Contact Us
Contact us if you have any questions regarding items or shipping.
Please visit our, EQT-Solutions’ web page to find additional assets.
Business hours and details: We will reply your message as quickly as we can.
However, please refer to our business hours in Finland: 8:30 - 16:00.