-40%

Hantek 4CH Digital Oscilloscope +EXT+DVM+Auto Range Function 80-250MHz Bandwidth

$ 221.23

Availability: 41 in stock
  • All returns accepted: Returns Accepted
  • Country/Region of Manufacture: China
  • Item must be returned within: 60 Days
  • Condition: New
  • Return shipping will be paid by: Buyer
  • Type: Analog Oscilloscope
  • Number of Channels: 4
  • Maximum Real-Time Sampling Rate: 1 GSa/s
  • MPN: Does Not Apply
  • Bandwidth: 80-250MHz
  • Brand: Hantek
  • Restocking Fee: No
  • Maximum Bandwidth: 250 MHz
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Channels: 4

    Description

    Feature:
    4CH oscilloscope+EXT+DVM+auto range function
    80-250MHz bandwidth,minimum range 500μV /div,1GS/s sample rate.
    Over 32 types of auto measurement function
    Advanced digital trigger system, high trigger sensitivity.
    Over 14 types of trigger function: edge, overtime, pulse, pattern, interval, etc.
    Function/
    arbitrary signal generator
    25MHz,12BitS resolution, 200MHz DDS, ARB/square wave/sine wave/
    triangular wave
    /
    trapezoidal wave
    /impulse wave/DC etc.,
    easy to simulate the sensor.
    Integrated USB Host/Device, convenient to communicate with PC. Support U-stick storage/systerm update.
    Support a variety of SCPI r
    emote control command
    Support optional RS232 port, LAN port, HDMI port, touch screen, WIFI communication, SD card storage
    Stable and reliable quality, sturdy and durable.
    Specification:
    Model
    DSO4254C
    DSO4204C
    DSO4104C
    DSO4084C
    Bandwidth
    250MHz
    200MHz
    100MHz
    80MHz
    Horizontal
    Sample Rate Range
    1GS/s
    Waveform Interpolation
    (sin x)/x
    Record Length
    Maximum 64K samples per single-channel;
    Maximum 32K samples per dual-channel (4K, 32K optional)
    SEC/DIV Range
    2ns/div~100s/div
    1, 2, 5 sequence
    Sample Rate and
    Delay Time Accuracy
    ±50ppm
    Delta Time Measurement Accuracy
    (Full Bandwidth)
    Single-shot, Normal mode
    ± (1 sample interval +100ppm × reading + 0.6ns)
    >16 averages
    ± (1 sample interval + 100ppm × reading + 0.4ns)
    Sample interval = s/div ÷ 200
    Vertical
    AD Converter
    8-bit resolution,
    each channel sampled simultaneously
    VOLTS/DIV Range
    500μV/div to 10V/div at input BNC
    Position Range
    500μV/div~20mV/div, ±400mV
    50mV/div~200mV/div, ±2V
    500mV/div~2V/div, ±40V
    5V/div~10V/div, ±50V
    Selectable Analog Bandwidth Limit, typical
    20MHz
    Low Frequency Response (-3db)
    ≤10Hz at BNC
    Rise Time at BNC, typical
    DSO4254C
    DSO4204C
    DSO4104C
    DSO4084C
    <1.4ns
    ≤1.8ns
    <3.5ns
    ≤4.4ns
    DC Gain Accuracy
    ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div
    ±4% for Normal or Average acquisition mode, 5mV/div to 500μV/div
    Note: Bandwidth reduced to 6MHz when using a 1X probe.
    Acquisition
    Acquisition Modes
    Normal, Peak Detect, Average and HR
    Acquisition Rate, typical
    Up to 2000 waveforms per second per channel (Normal acquisition mode, no measurement)
    Single Sequence
    Acquisition Mode
    Acquisition Stop Time
    Normal, Peak Detect
    Upon single acquisition on all channels simultaneously
    Average
    After N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128
    Trigger
    Mode
    Auto, Normal
    Level
    CH1~CH4
    ±4 divisions from center of screen
    EXT
    0~3.3V
    Holdoff Range
    20ns ~ 10s
    Trigger Level Accuracy
    CH1~CH4
    0.2div × volts/div within ±4 divisions from center of screen
    EXT
    ± (6% of setting + 40mV)
    Edge Trigger
    Slope
    Rising, Falling, Rising&Falling
    Source
    CH1~CH4/EXT
    Pulse Width
    Polarity
    Positive, Negative
    Condition(When)
    <, >, !=, =
    Source
    CH1~CH4
    Width Range
    8ns ~ 10s
    Resolution
    8ns
    Video Trigger
    Signal Standard
    NTSC, PAL
    Source
    CH1~CH4
    Sync
    ScanLine, LinrNum, OddField, EvenField and AllField
    Slope Trigger
    Slope
    Rising, Falling
    Condition(When)
    <, >, !=, =
    Source
    CH1 ~ CH4
    Time Range
    8ns ~ 10s
    Resolution
    8ns
    Overtime Trigger
    Source
    CH1~CH4
    Polarity
    Positive, Negative
    Time Range
    8ns ~ 10s
    Resolution
    8ns
    Window Trigger
    Source
    CH1~CH4
    Pattern Trigger
    Pattern
    0: Lower level; 1: High level;
    Level
    CH1~CH4
    Interval Trigger
    Slope
    Rising, Falling
    Condition(When)
    <, >, !=, =
    Source
    CH1~CH4
    Time Range
    8ns ~ 10s
    Resolution
    8ns
    Under Amp
    Polarity
    Positive, Negative
    Condition(When)
    <, >, !=, =
    Source
    CH1~CH4
    Time Range
    8ns ~ 10s
    Resolution
    8ns
    UART Trigger
    Condition(When)
    Start, Stop, Data, Parity Error, COM Error
    Source(RX/TX)
    CH1~CH4
    Data format
    Hex
    Condition(When)
    <, >, !=, =
    Data Length
    1 byte
    Data Length
    5 bit, 6 bit, 7 bit, 8 bit
    Parity Check
    None, Odd, Even
    Idle Level
    High, Low
    Baud Rate(Selectable)
    110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s
    Baud Rate (Custom)
    300bit/s~334000bit/s
    LIN Trigger
    Condition(When)
    Interval Field, Sync Field, Id field, Sync Id Error, Identifier, Id and Data
    Source
    CH1~CH4
    Data format
    Hex
    Baud Rate (Selectable)
    110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s
    Baud Rate (Custom)
    300bit/s~334000bit/s
    CAN Trigger
    Condition(When)
    Start Bit, Remote Frame, Data Frame Id, Frame Id, DataFrame Id A, Error Frame, All Error, Ack Error, Overload Fram
    Source
    CH1~CH4
    Data format
    Hex
    Baud Rate (Selectable)
    10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000
    Baud Rate (Custom)
    5kbit/s~1Mbit/s
    SPI Trigger
    Source (CS/CLK/Data)
    CH1~CH4
    Data format
    Hex
    Data Length
    4, 8, 16, 24, 32
    IIC Trigger
    Source (SDA/SCL)
    CH1~CH4
    Data format
    Hex
    Data Index
    0~7
    When(Condition)
    Start, Stop, No Ack, Address, Data, Restart
    Inputs
    Input Coupling
    DC、AC or GND
    Input Impedance, DC coupled
    20pF±3 pF,1MΩ±2%
    Probe Attenuation
    1X、10X
    Supported Probe Attenuation Factors
    1X、10X、100X、1000X
    Overvoltage Category
    300V CAT II
    Maximum Input Voltage
    300V
    RMS
    (10X)
    Measurements
    Cursors
    Voltage difference between cursors: △V
    Time difference between cursors: △T
    Reciprocal of △T in Hertz (1/ΔT)
    Automatic Measurements
    Frequency, Period, Average, Pk-Pk, RMS, PeriodRms, Min, Max, RiseTime, FallTime, + Width, - Width, + Duty, - Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, PeriodAvg, FOVShoot, RPREShoot, BWidth, FRR, FFF, FRF, FFR, LRR, LRF, LFR and LFF
    General Specifications
    Display
    Display Type
    7 inch 64K color TFT (diagonal liquid crystal)
    Display Resolution
    800 horizontal by 480 vertical pixels
    Display Contrast
    Adjustable
    Probe Compensator Output
    Output Voltage, typical
    About 2Vpp into ≥1MΩ load
    Frequency, typical
    1kHz
    Power Supply
    Supply Voltage
    100-120VACRMS(±10%),45Hz to 440Hz,CATⅡ
    120-240VACRMS(±10%),45Hz to 66Hz,CATⅡ
    Power Consumption
    <30W
    Fuse
    T,3.15A,250V,5x20mm
    Environmental
    Operating Temperature
    0~50 °C (32~122 °F)
    Storage Temperature
    -40~+71 °C (-40~159.8 °F)
    Humidity
    ≤+104℉(≤+40°C): ≤90% relative humidity
    106℉~122℉ (+41°C ~50°C): ≤60% relative humidity
    Cooling Method
    Convection
    Altitude
    Operating and Nonoperating
    3,000m(10,000 feet)
    Random Vibration
    0.31g
    RMS
    from 50Hz to 500Hz,
    10 minutes on each axis
    Nonoperating
    2.46g
    RMS
    from 5Hz to 500Hz
    10 minutes on each axis
    Mechanical Shock
    Operating
    50g, 11ms, half sine
    Mechanical
    Dimension
    318 x 110 x 150mm(L x W x H)
    Weight
    2900g
    Arbitrary Waveform Generator Mode
    Waveform Frequency
    Sine: 0.1Hz~25MHz
    Square: 0.1Hz~10MHz
    Ramp: 0.1Hz~1MHz
    EXP: 0.1Hz~5MHz
    Amplitude
    5mV~3.5Vp-p(50Ω)
    10mV~7Vp-p(High impedance)
    DAC
    2K~200MHz adjustable
    Frequency Resolution
    0.001
    Channel
    1CH waveform output
    Waveform Depth
    4KSa
    Vertical Resolution
    12 bit
    Frequency Stability
    <30ppm
    Output Impedance
    50 Ω
    Package:
    1 x DSO4104C oscilloscope;
    4 x probe;
    1 x bnc cable;
    1 x usb cable;
    1 x power cable;
    1 x english manual