-40%

Hantek 2 Channels Digital Handheld Oscilloscope Multimeter 60/100/200MHz 1Gsa/S

$ 204.86

Availability: 40 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: Hantek
  • Sample Rate: 1GSa/s
  • Maximum Real-Time Sampling Rate: 1 GSa/s
  • Channels: 2
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Type: Digital Storage Oscilloscope (DSO)
  • Country/Region of Manufacture: China
  • Oscilloscope Type: Digital Oscilloscope
  • Maximum Bandwidth: 200 MHz
  • Item must be returned within: 60 Days
  • Model: DSO1000B
  • MPN: Does Not Apply
  • Condition: New

    Description

    DSO1000B Series
    60MHz-200MHz Bandwidth Oscilloscope;
    1GSa/s sample rate, 1M Memory Depth, and 6000 Counts DMM with analog bargraph;
    5.6 inch TFT Color LCD Display, high resolution(640*480).
    High Bandwidth 60MHz-200MHz Oscilloscope, 1GS/s sample rate, and 6000 Counts DMM with analog bargraph.
    1M Memory Depth.
    High Refresh Rate (2500 frames).
    Large 5.6 inch TFT Color LCD Display; High Resolution(640*480); Dual-Window Design --More clear, More Detailed.
    One-touch automatic setup optimizes the position, range, timebase, and triggering to assure a stable display of virtually any waveform.
    Easy-to-use pop-up menu with built-in multi-language help system.
    32 Automatic Measurements.
    Waveform Math: Add, Subtract, Multiply, and Divide.
    Store and recall over.
    Automatic cursor tracking measurements.
    XY Mode.
    Built-in FFT function converts a time-domain signal into its frequency components to measure harmonic content and distortion in systems.
    Waveform Recorder to capture/replay input waveforms from CH1 and CH2 with a maximum record length of 1000 frames.
    Pass/Fail function compares a stored waveform to an unknown input.
    Average Mode for smoothing waveforms.
    Square Wave Output (2V, 1kHz) for probe adjustment.
    USB Host/Device 2.0 full-speed interface ,support removeable disk, LAN Optional ,Easy to control by PC or long-distance.
    Dimensions (mm):240(L)x165(W)x50(H), be carried easily.
    Model
    DSO1202B
    DSO1102B
    DSO1062B
    Acquisition
    Sample Modes
    Real-Time Sample: 1GS/s;
    Equivalent Sample: 25GS/s
    Acquisition Modes
    Normal
    Normal data only
    Peak Detect
    High-frequency and randon glith capture
    Average
    Wavefom Average, selectable 4,8,16,32,64,128
    Inputs
    Inputs Coupling
    AC, DC, GND
    Inpits Impendance
    1MΩ±2% ‖20pF±3pF
    Probe Attenuation
    1X, 10X
    Supported Probe Attenuation Factor
    1X, 10X, 100X, 1000X
    Maximum Input Voltage
    CAT I and CAT II: 300VRMS (10×), Installation Category;
    CAT III: 150VRMS (1×);
    Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
    Horizontal
    Sample Rate Range
    500MS/s--1GS/s
    Waveform Interpolation
    (sin x)/x
    Record Length
    1M
    SEC/DIV Range
    2ns/div~2000s/div,
    4ns/div~2000s/div,
    Sample Rate and
    Delay Time Accuracy
    500ps(at over any ≥1ms time interval)
    Position Range
    2ns/div to10ns/div;
    (-4div×s/div) to 20ms;
    4ns/div to 8ns/div; (-8div x s/div) to 40ms;
    20ns/div to 80μs /div;(-8div×s/div)to 40ms;
    200μs/div to 40s/div; (-8div×s/div)to 400s;
    Delta Time Measurement Accuracy
    (Full Bandwidth)
    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
    >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
    Sample interval = s/div ÷ 200
    Vertical
    Vertical Resolution
    8-bit resolution, all channel sampled simultaneously
    Position Range
    2mV/div to 200mV/div, ±2V
    200mV/div to 5V/div, ±50V
    Bandwidth
    200MHz
    100MHz
    60MHz
    Rise Time at BNC( typical)
    1.8ns
    3.5ns
    5.8ns
    Analog Bandwidth in
    Normal and Average
    modes at BNC or with probe, DC Coupled
    2mV/div to 20mV/div, ±400mV;
    50mV/div to 200mV/div, ±2V;
    500mV/div to 2V/div, ±40V;
    5V/div, ±50V
    Math
    +, -, *, /, FFT
    FFT
    Windows: Hanning、Flatop、Rectamgular、Bartlett、Blackman; 1024 sample point
    Bandwidth Limit
    20MHz
    Low Frequency Response (-3db)
    ≤10Hz at BNC
    DC Gain Accuracy
    ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
    ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
    DC Measurement Accuracy,
    Average Acquisition Mode
    When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
    When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
    Volts Measurement Repeatability,
    Average Acquisition Mode
    Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
    Trigger
    Trigger Types
    Edge, Video, Pulse, Slope, Over time, Alternative
    Trigger Source
    CH1, CH2, AC Line
    Trigger Modes
    Auto, Normal
    Coupling Type
    DC, AC, Noise Reject, HF Reject, LF Reject
    Trigger Sensitivity
    (Edge Trigger Type)
    DC(CH1,CH2):
    1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
    AC: Attenuates signals below 10Hz ;
    HF Reject: Attenuates signals above 80kHz;
    LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
    Trigger Level Range
    CH1/CH2: ±8 divisions from center of screen;
    Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns
    CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
    Set Level to 50%(typical)
    Operates with input signals ≥50Hz
    Video Trigger
    Video Trigger Type
    CH1, CH2: Peak-to-peak amplitude of 2 divisions;
    Signal Formats and Field Rates, Video Trigger Type
    Supports NTSC, PAL and SECAM broadcast systems for any field or any line
    Holdoff Range
    100ns ~ 10s
    Pulse Width Trigger
    Pulse Width Trigger Mode
    Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
    Pulse Width Trigger Point
    Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
    Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
    Less than: The trigger point is the trailing edge.
    Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
    Pulse Width Range
    20ns ~ 10s
    Slope Trigger
    Slope Trigger Mode
    Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
    Slope Trigger Point
    Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
    Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
    Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
    Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
    Time Range
    20ns ~ 10s
    Overtime Trigger
    Over Time Modee
    Rising edge or Falling edge
    Time Range
    20ns ~ 10s
    Alternative Trigger
    Trigger on CH1
    Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger on CH2
    Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger Frequency Counter
    Readout Resolution
    6 digits
    Accuracy (typical)
    ±30ppm (including all frequency reference errors and ±1 count errors)
    Frequency Range
    AC coupled, from 4Hz minimum to rated bandwidth
    Signal Source
    Pulse Width or Edge Trigger modes: all available trigger sources
    The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
    Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
    Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
    Video Trigger mode: The Frequency Counter does not work.
    Measure
    Cursor Measurement
    Voltage difference between cursors: △V
    Time difference between cursors: △T
    Reciprocal of △T in Hertz (1/ΔT)
    Auto Measuerment
    Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
    General Features
    Display
    Display Resolution
    640 horizontal by 480 vertical pixels
    Display Contrast
    Adjustable (16 gears) with the progress bar
    Probe Compensator Output
    Output Voltage( typical)
    About 5Vpp into ≥1MΩ load
    Frequency(typical)
    1kHz
    Power Supply
    Supply Voltage
    AC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A
    Power Consumption
    <30W
    Environmental
    Temperature
    Operating: 32℉ to 122℉ (0℃ to 50℃);
    Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
    Cooling Method
    Convection
    Humidity
    +104℉ or below (+40℃ or below): ≤90% relative humidity;
    106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
    Altitude
    Operating: Below 3,000m (10,000 feet);
    Nonoperaring: Below 15,000m(50,000 feet)
    Mechanical
    Size
    Length 245mm; Width 163mm; Height 52mm
    Weight
    2.8KG(with Packing); 1.2KG(without Packing)
    DMM Mode
    Max. Resolution
    6000 Counts
    DMM Testing Modes
    Voltage, Current, Resistance, Capacitance, Diode & Continuity
    Max. Input Voltage
    AC:600V, DC: 800V
    Max. Input Current
    AC: 10A, DC:10A
    Input Impedance
    10MΩ
    DMM
    TrendPlot
    1.2M Point
    Range
    Resolution
    Accuracy
    Resolution
    DC Voltage
    60.00mV
    ±1%±3 digit
    10uV
    600.0mV
    100uV
    6.000V
    1mV
    60.00V
    10mV
    600.0V
    100mV
    800V
    1V
    AC Voltage
    60.00mV
    ±1%±3 digit
    10uV
    600.0mV
    100uV
    6.000V
    1mV
    60.00V
    10mV
    600.0V
    100mV
    DC Current
    60.00mA
    ±1%±5 digit
    10uA
    600.0mA
    ±1.5%±5 digit
    100uA
    6.000A
    1mA
    10.00A
    10mA
    AC Current
    60.00mA
    ±1%±5 digit
    10uA
    600.0mA
    ±1.5%±5 digit
    100uA
    6.000A
    1mA
    10.00A
    10mA
    Resistance
    600
    Ω
    ±1%±3 digit
    0.1Ω
    6.000K
    Ω

    60.00K
    Ω
    10Ω
    600.0K
    Ω
    1KΩ
    6.000M
    Ω
    10KΩ
    60.00M
    Ω
    ±1%±5 digit
    100KΩ
    Capacitance
    40.00nF
    ±2%±5 digit
    10pF
    400.0nF
    100pF
    4.000uF
    1nF
    40.00uF
    10nF
    400.0uF
    100nF
    Attention: the smallest capacitance value that can be measured in 5nF
    Diode
    0V~2.0V
    ON-OFF test
    <10Ω