-40%

2in1 Hantek MSO5202D 200MHz 2 Ch 1GSa/s Digital Oscilloscope 16Ch Logic Analyzer

$ 225.71

Availability: 100 in stock
  • Number of Channels: 2
  • Digital Oscilloscope Resolution: 12-bit
  • All returns accepted: Returns Accepted
  • MPN: MSO5202D
  • Oscilloscope Type: Mixed Signal Oscilloscope (MSO)
  • Return shipping will be paid by: Buyer
  • Condition: New
  • Country/Region of Manufacture: China
  • Brand: HANTEK
  • Restocking Fee: No
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Maximum Bandwidth: 200 MHz
  • Item must be returned within: 60 Days
  • Maximum Real-Time Sampling Rate: 1 GSa/s
  • Model: oscilloscope
  • Features: Handheld/ Portable

    Description

    2in1 Hantek MSO5202D 200MHz 2 Ch 1GSa/s Digital Oscilloscope 16Ch Logic Analyzer
    1.Feature
    16 channels logic analyzer + 2 channels oscilloscope + external trigger.
    Big and clear display (7.0-inch color LCD, high revolution 800 x 480), clear lifelike waveform display.
    1GSa/s real time sampling rate.
    USB host, support flash memory card storage and USB interface system upgrade.
    Ultrathin design, handy volume, easily portable.
    VGA Optional
    Oscilloscope Function
    Bandwidth 200MHz.
    Each channel record length up to 1M.
    Real time sampling rate up to 1GSa/s.
    Powerful trigger function.
    32 kinds of automatic measurement function.
    Logic Analyzer Function
    16 channels divided into 2 groups which is able to setup threshold level individually.
    Real time sampling rate up to 500MSa/s.
    Powerful trigger function: edge, duration, pulse width, code-type, queen, repeat.
    2. Specification
    Model
    MSO5202D
    Acquisition
    Sample Rate
    Real-Time Sample: 1GS/s
    Acquisition Modes
    Normal
    Normal data only
    Peak Detect
    High-frequency and randon glith capture
    Average
    Wavefom Average, selectable 4,8,16,32,64,128
    Inputs
    Inputs Coupling
    AC, DC, GND
    Inputs Impendance
    1MΩ±2% II20pF±3pF
    Probe Attenuation
    1X, 10X
    Supported Probe Attenuation Factor
    1X, 10X, 100X, 1000X
    Maximum Input Voltage
    CAT I and CAT II: 300VRMS (10×), Installation Category;
    CAT III: 150VRMS (1×);
    Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
    Horizontal System
    Sample Rate Range
    500MS/s--1GS/s
    Waveform Interpolation
    (sin x)/x
    Record Length
    1M
    SEC/DIV Range
    2ns/div to 40s/div, in a 2, 4, 8 sequence,
    Sample Rate and
    Delay Time Accuracy
    ±50ppm(at over any ≥1ms time interval)
    Position Range
    2ns/div to 10ns/div;
    (-4div x s/div) to 20ms;
    Delta Time Measurement Accuracy
    (Full Bandwidth)
    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
    >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
    Sample interval = s/div ÷ 200
    Vertical System
    Vertical Resolution
    8-bit resolution, all channel sampled simultaneously
    Position Range
    2mV/div to 10V/div
    Bandwidth
    200MHz
    Rise Time at BNC( typical)
    1.8ns
    Analog Bandwidth in
    Normal and Average
    modes at BNC or with probe, DC Coupled
    2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V
    500mV/div to 2V/div, ±40V; 5V/div, ±50V
    Math
    +, -, *, /, FFT
    FFT
    Windows:Hanning,Flatop, Rectamgular,Bartlett,Blackman;
    1024 sample point
    Bandwidth Limit
    20MHz
    Low Frequency Response (-3db)
    ≤10Hz at BNC
    DC Gain Accuracy
    ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div;
    ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
    DC Measurement Accuracy,
    Average Acquisition Mode
    When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
    When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div
    Volts Measurement Repeatability,
    Average Acquisition Mode
    Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
    Trigger System
    Trigger Types
    Edge, Video, Pulse, Slope, Over time, Alternative
    Trigger Source
    CH1, CH2, EXT, EXT/5, AC Line
    Trigger Modes
    Auto, Normal, Single
    Coupling Type
    DC, AC, Noise Reject, HF Reject, LF Reject
    Trigger Sensitivity
    (Edge Trigger Type)
    DC(CH1,CH2):
    1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
    DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
    DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
    AC: Attenuates signals below 10Hz;
    HF Reject: Attenuates signals above 80kHz;
    LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
    Trigger Level Range
    CH1/CH2: ±8 divisions from center of screen;
    EXT: ±1.2V;
    EXT/5:±6V
    Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns
    CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
    EXT: ± (6% of setting + 40mV);
    EXT/5: ± (6% of setting + 200mV);
    Set Level to 50%(typical)
    Operates with input signals ≥50Hz
    Video Trigger
    Video Trigger Type
    CH1, CH2: Peak-to-peak amplitude of 2 divisions;
    EXT: 400mV;
    EXT/5: 2V
    Signal Formats and Field Rates, Video Trigger Type
    Supports NTSC, PAL and SECAM broadcast systems for any field or any line
    Holdoff Range
    100ns ~ 10s
    Pulse Width Trigger
    Pulse Width Trigger Mode
    Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
    Pulse Width Trigger Point
    Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
    Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
    Less than: The trigger point is the trailing edge.
    Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
    Pulse Width Range
    20ns ~ 10s
    Slope Trigger
    Slope Trigger Mode
    Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
    Slope Trigger Point
    Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
    Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
    Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
    Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
    Time Range
    20ns ~ 10s
    Overtime Trigger
    Over Time Mode
    Rising edge or Falling edge
    Time Range
    20ns ~ 10s
    Alternative Trigger
    Trigger on CH1
    Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger on CH2
    Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger Frequency Counter
    Readout Resolution
    6 digits
    Accuracy (typical)
    ±30ppm (including all frequency reference errors and ±1 count errors)
    Frequency Range
    AC coupled, from 4Hz minimum to rated bandwidth
    Signal Source
    Pulse Width or Edge Trigger modes: all available trigger sources
    The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
    Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
    Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
    Video Trigger mode: The Frequency Counter does not work.
    Measurement
    Cursor Measurement
    Voltage difference between cursors: ΔV
    Time difference between cursors: ΔT
    Reciprocal of ΔT in Hertz (1/ΔT)
    Auto Measuerment
    Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
    Logic Analyzer Specifications
    Channels
    16 Channels
    Max. Input Impendence
    200K(C=10p)
    Input Voltage Range
    -60V~60V
    Logic Threshold Range
    -8V~8V
    Max. Sample Rate
    500MHz
    Compatible Input
    TTL, CMOS, ECL
    Sample Depth
    512K
    Trigger
    Edge Trigger
    D0-D15 select slope (rising or falling edge)
    Pulse Width
    D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width
    Code-type
    D0-D15 select code-type (H, L, X)
    Duration
    D0-D15 select persist time and trigger when (data terminate, data start, and data delay)
    Queue
    D0-D15 select specific data index (0-3) and code-type (H, L, X)
    Repeat
    D0-D15 select code-type (H, L, X) and repeat times
    General Features
    Display
    Display Type
    7 inch 64K color TFT (diagonal liquid crystal)
    Display Resolution
    800 horizontal by 480 vertical pixels
    Display Contrast
    Adjustable (16 gears) with the progress bar
    Probe Compensator Output
    Output Voltage( typical)
    About 5Vpp into ≥1MΩ load
    Frequency(typical)
    1kHz
    Power Supply
    Supply Voltage
    100-120VACRMS(±10%), 45Hz to 440Hz, CATII
    120-240VACRMS(±10%), 45Hz to 66Hz, CATII
    Power Consumption
    <30W
    Fuse
    2A, T rating, 250V
    Environmental
    Temperature
    Operating: 32 to 122
    °F
    (0 to 50
    °C
    );
    Nonoperating: -40 to 159.8
    °F
    (-40 to +71
    °C
    )
    Cooling Method
    Convection
    Humidity
    +104
    °F
    or below (+40
    °C
    or below): ≤90% relative humidity;
    106 to 122
    °F
    (+41 to 50
    °C
    ): ≤60% relative humidity
    Altitude
    Operating: Below 3,000m (10,000 feet);
    Nonoperaring: Below 15,000m(50,000 feet)
    Size & Wight
    Size
    385mm x 200mm x 245mm
    Weight
    2.08KG(without Packing)
    Package (gift box):
    1 x 5202D oscilloscope
    2 x oscilloscope probe
    1 x USB cable
    1 x power cable
    1 x CD  & manual