-40%

100MHz 2Channels 1GSa/s Oscilloscope 16Channels Logic Analyzer 2in1 MSO5102D USB

$ 234.96

Availability: 100 in stock
  • Model: MSO5102D
  • Country of Manufacture: China
  • Sample Rate: 1GSa/s - 1.9GSa/s
  • Country/Region of Manufacture: China
  • Type: Digital
  • Item must be returned within: 30 Days
  • Brand: Hantek
  • Restocking Fee: No
  • Refund will be given as: Money Back
  • Condition: New
  • MPN: MSO5102D
  • Number of Channels: 2
  • All returns accepted: Returns Accepted
  • Bandwidth: 100MHz - 349MHz
  • Channels: 2
  • Return shipping will be paid by: Buyer

    Description

    MSO5102D
    Features:
    16 channels logic analyzer + 2 channels oscilloscope + external trigger
    .
    Big and clear display (
    7.0-inch color LCD, high revolution 800 x 480
    ), clear
    lifelike waveform display.
    1GSa/s real time sampling rate.
    100MHz bandwidth, 1M memory depth.
    Powerful
    trigger function.
    USB
    host, support flash memory card storage and USB interface system upgrade.
    Ultrathin
    design, handy volume, easily portable.
    Oscilloscope Function
    Bandwidth 1
    00MHz.
    Each channel record length up to 1M.
    Real time sampling rate up to
    1GSa/s.
    Powerful
    trigger function.
    More than 20 kinds of automatic measurement function.
    Logic Analyzer Function
    16 channels
    divided into 2 groups which is able to setup threshold level individually.
    Real time sampling rate up to
    500MSa/s
    .
    Powerful
    trigger function: edge, duration, pulse width, code-type, queen, repeat.
    Specification
    Oscilloscope Specification
    Horizontal
    Model
    MSO5062D
    MSO5102D
    MSO5202D
    Bandwidth
    60MHz
    100MHz
    200MHz
    Sampling Rate Range
    Max. 1GS/s
    Waveform
    Interpolation
    ( sin x) /x
    Memory Depth (Sample Points)
    Single-channel: maximum 1M; Dual-channel: maximum 512K (4K, 16K, 40K optional)
    SEC/DIV Range
    8ns/div-40s/div (stepping in a sequence: 2,4,8)
    Sampling Rate and Delay Time Accuracy
    ±50ppm in any ≥1ms time intervals
    Delta Time Measurement Accuracy (full bandwidth)
    Single, "sampling" mode
    ± (1 sampling interval + 100ppm × readings + 0.6 ns)
    > 16 times above average
    ± (1 sampling interval + 100ppm × readings + 0.4 ns)
    Sampling interval = SEC/DIV÷200
    Vertical
    A/D Converter
    8-bit resolution, each channel sampled simultaneously
    VOLTS/DIV Range
    2mV/div ~ 5V/div at input BNC
    Position Range
    ±400mV (2mV/div ~20mV/div)
    ±2V (50mV/div ~200mV/div)
    ±40V (500mV/div ~2V/div)
    ±50V (5V/div)
    Optional Analog Bandwidth Limit (typical)
    20MHz
    Low Frequency
    Response (-3db)
    ≤10Hz at output BNC
    Rising Time at output BNC (typical)
    60MHz
    100MHz
    200MHz
    ≤ 5.8ns
    <3.5ns
    <1.8ns
    Vertical Gain Accuracy
    ±3% for sample or average acquisition mode, 5V/div to 10mV/div;
    ±4% for sample or average acquisition mode, 5mV/div to 2mV/div
    DC Measurement Accuracy
    Average Acquisition Mode
    Measuring type: ≥16 zero vertical position waveform average .
    Accuracy: ± (3%× reading+ 0.1div+ 1 mV), applicable to 10 mV/div or above units.
    Measuring type: ≥16 non-zero vertical position waveform average.
    Accuracy: ± [3%× (readings+ vertical position)+1%×vertical position+0.2div].
    For the setting from 2mV/div to 200mV/div, +2mV; for 200mV/div to 5V/div, +50mV.
    Voltage Measurement Repeatability
    Average Acquisition Mode
    In the same settings and environmental conditions, acquisition ≥ the voltage increment between any two groups average of 16 above waveforms : ± (3% × readings + 0.05 div)
    Trigge
    r
    Trigger Sensitivity (Edge Trigger Type)
    Coupling
    Sensitivity
    DC
    Source
    60MHz
    100MHz
    200MHz
    CH1
    CH2
    1div from DC to 10MHz, 1.5div from 10MHz to Full
    1.5div from 10MHz to 100MHz, 2div from 100MHz to Full
    EXT
    200mV from DC to 100MHz
    200mV from DC to 100MHz, 350mV from 100MHz to 200MHz
    EXT/5
    1V from DC to 100MHz
    1V from DC to 100MHz, 1.75V from 100MHz to 200MHz
    AC
    Attenuates signals below 10Hz
    HF Reject
    Attenuates signals when above 80kHz
    LF Reject
    The same as DC coupling limit when frequency above 150kHz; Attenuates signals when below 150kHz.
    Trigger Level Range
    Source
    Range
    CH1, CH2
    ±8 divisions from center of screen
    EXT
    ±1.2V
    EXT/5
    ±6V
    Trigger Level Accuracy, typical (Accuracy is for signals having rise and fall time ≥ 20ns)
    Source
    Accuracy
    CH1, CH2
    ±(0.2div × V/div) (within ±4 divisions from center of screen)
    EXT
    ±(6% of setting+40mV)
    EXT/5
    ±(6% of setting+200mV)
    Set Trigger Level to 50% (typical)
    For the input signals ≥ 50Hz
    Video Trigger Type
    Source
    Range
    CH1, CH2
    The amplitude of 2 points peak-peak
    EXT
    400mV
    EXT/5
    2V
    Signal Format , Field Rate and Video Trigger Type
    Any field or any line support NTSC PAL and SECAM
    Holdoff Range
    100ns-10s
    Pulse Width Trigger
    Mode
    When <, >, =, or ≠ trigger; positive or negative pulses.
    Trigger Point

    : Triggers when pulse falling edge over trigger level.
    ≠: If the pulse narrower than the appointed width, the trigger point is the falling edge; or triggers when the pulse duration longer than the width setting time.
    < : Triggers when the pulse duration less than the width setting time.
    >(Also called overtime trigger): Triggers when pulse is greater than width setting.
    Range
    20ns ~10s
    Slope Trigger
    mode
    When <, >, =, or ≠ trigger; positive or negative slopes.
    Trigger Point

    : Triggers when waveform slope is equal to slope setting.
    ≠: Triggers when waveform slope is not equal to slope setting.
    <: Triggers when waveform slope is less than slope setting.
    >: Triggers when waveform slope is greater than slope setting.
    Range
    20ns-10s
    Overtime Trigger
    From the rising or falling edge; Setup time: 20-10 s
    Alternative Trigger
    CH1
    Internal trigger: edge, pulse, video, or slop
    CH2
    Internal trigger: edge, pulse, video, or slop
    Trigger Frequency Counter
    Readout Resolution
    6bit
    Accuracy (typical)
    ±30ppm (Including all of the frequency reference error and ±1 calculation error)
    Frequency Range
    AC coupling, from minimum 4Hz to specified bandwidth
    Source
    "Pulse width" or "edge trigger" mode: all available trigger source
    "Frequency counter" is always measuring the trigger source, even when oscilloscope acquisition paused because of the operation state’s changing, or when a single acquisition finished.
    The “pulse width" trigger mode: the oscilloscope calculates the pulses whose window having effective amplitude, which measure at 1s and meet trigger condition. For example, if the PWM pulse line is set to < mode, and width is correspondingly set to smaller time, then the narrow pulse among them is the one to be calculated.
    "Edge trigger" mode: the oscilloscope calculates all the edge with sufficient amplitude and correct polarity.
    "Video trigger" mode: "frequency counter" doesn't work.
    Acquisition
    Mode
    Sample, Peak value detection and Average
    SINGLE SEQ
    Acquisition Mode
    Acquisition Stop Time
    Sample, peak value detect
    All communications start to single acquisition simultaneously
    Average
    All communications start to N times acquisition simultaneously, and N could be 4, 8, 16, 32, 64 or 128
    Input
    Input Coupling
    DC, AC or GND
    Input Impedance, DC Coupling
    1MΩ±2% for 20pF±3 pF
    Probe Attenuation
    1X, 10X
    Support Probe Attenuation Coefficients
    1X, 10X, 100X, 1000X
    Max. Input Voltage
    Overvoltage Type
    Max. Voltage
    CAT I and CAT II
    Installation type: 300V
    RMS
    (10×)
    CAT III
    150V
    RMS
    (1×)
    Installation type Ⅱ: Take 20 dB/decade as slope, from 100kHz above begins to decline to ≥ 3MHz *, the AC peak value is 13V. For the non-sine waveforms, the peak value must less than 450V. Above 300V the offset duration should be less than 100ms. RMS signal level (including all the DC component delete by the AC coupling) must be limited to 300V. If beyond these values, it may damage the device.
    Measurement
    Cursors
    The difference between voltage cursors △V; the difference between time cursors △T; 1/△T calculated by Hz.
    Automatic
    Frequency, Period, Mean, Pk-Pk, Cyc RMS, Min, Max, Rise Time, Fall Time, Positive Width, Negative Width.
    General
    Display
    Type
    7” TFT, 64K true color LCD
    Resolution
    800x480 dots
    Contrast
    16 gears with the progress bar to show adjustment
    Probe Compensator Output
    Output Voltage (typical)
    About 5Vpp input ≥ 1 M Ω load
    Frequency (typical)
    1kHz
    Power Supply
    Voltage
    100-120VAC
    RMS
    (±10%),45Hz to 440Hz, CATⅡ
    120-240VAC
    RMS
    (±10%),45Hz to 66Hz, CATⅡ
    Power
    < 30W
    Fuse
    2A, T rating, 250V
    Environment
    Temperature
    Working: 32

    to 122
    ℉ (0℃ to 50℃)
    Not working: -40

    to 159.8

    (-40

    to +71

    )
    Cooling Type
    Convection
    Humidity
    + 104

    or below (+ 40

    or below) :
    ≤ 90% relative humidity
    + 106

    to 122

    (+ 40

    to 50

    ) :
    ≤ 60% relative humidity
    Sea Level Height
    Working and Not working
    3,000m (10,000 foot)
    Random Vibration
    50
    Hz to 500 Hz: 0.31 g RMS, each axial: 10 minutes
    Not working
    5 Hz to 500 Hz: 2.46 g RMS, each axial: 10 minutes
    Mechanical Shock
    Working
    50g, 11ms, half-sine wave
    Mechanical
    Dimension
    Length
    313mm
    Height
    142mm
    Thickness
    108mm
    Weight
    Not including the weight of package and accessories
    2.08Kg
    Packing Dimension
    Length
    395mm
    Width
    410mm
    Height
    275mm
    Gross Weight
    Including all accessories
    about 3.2kg
    Logic Analyzer Specification
    Sampled Channels
    16
    ( divided into 2 groups)
    Max. Input Impedance
    200K (C=10p)
    Input Voltage Range
    -60V~60V
    Logic Threshold Range
    -8V~8V
    Max. Sample Rate
    500MHz
    Compatible Input
    TTL, CMOS, ECL
    Sample Depth
    512KSample
    Cursors
    The difference between voltage cursors △V; the difference between time cursors △T; 1/△T calculated by Hz.
    Measurement
    Period and Frequency
    Record Position
    RefA
    RefB
    Trigger
    Edge
    D0-D15 select slope (rising or falling edge)
    Pulse Width
    D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width
    Code-type
    D0-D15 select code-type (H, L, X)
    Duration
    D0-D15 select persist time and trigger when (data terminate, data start, and data delay)
    Queue
    D0-D15 select specific data index (0-3) and code-type (H, L, X)
    Repeat
    D0-D15 select code-type (H, L, X) and repeat times
    Operating system: Windows 7, Windows NT, Windows 2000, Windows XP,
    VISTA
    Accessories: probes for logic analyzer, 2 probes for scope, 1 USB cable, 1 power cord, 1 CD
    Note:
    1.W
    ill ship
    to
    USA
    via
    DHL or Fedex
    (not for PO Box or APO or FPO), delivery time is about
    7 days.
    2. Will ship via
    express mail service
    to Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea, Thailand, Malaysia, Indonesia, Philippine and Singapore customers.
    3. Customers from other countries pls contact us in advance to confirm different shipping charges before you order.